Iris Management Suite
Technical Guide V1.7C 4/11/07
18
The Last Valid Key field shows the actual key in use by
the dialler. Note this field is only refreshed when this
window is opened.
For maximum security it is recommended that the key
length should be 32 characters, each dialler has a unique
key and all keys are changed regularly.
4 Set main and backup
Polling Engines for this
dialler
See section below for more details. Can be changed at
any time and changes will be sent to the dialler when it
next polls in.
5 Sets polling interval Note that extended polling intervals (above 40 minutes)
are only supported by diallers version 2.12 and above.
6 Automatically adds more
database entries
Database entries will be added in incremental numerical
order from the one displayed. All parameters (security
key etc) will be the same.
7 Save or delete dialler Save current dialler settings or delete current dialler
8 Free text area for
description of dialler
For reference only, e.g. site details, customer details, key
holder info etc
9 Dialler remote access
functions
A set of commands that activate remote access functions
for the dialler, e.g. configuration over IP or access to
alarm panel for upload/download.
See section below for more detail.
10 Sets which dialler
interfaces are monitored
so that status changes
are reported to ARC as
Trouble/Restore.
ISDN: Dialler interface to ISDN line.
PSTN: Dialler interface to PSTN line.
Ethernet: Dialler interface to Ethernet.
GPRS: Dialler interface to GPRS network.
Panel: Dialler two wire interface to panel, short or open
circuit detection – note this requires sense resistor to be
fitted at the panel end of the connection – see IRIS
Dialler Installation Guide- applies to diallers version 2.8
and later.
Pin Inputs: Dialler pin input short or open circuit detection
- note this requires sense resistors to be fitted at the
remote end of the input lines – see IRIS Dialler
Installation Guide – applies to diallers version 2.12 and
later.
Note - the actual interfaces available on a dialler depend
on the actual dialler type (IRIS 800, 840 etc).
11 Shows current dialler
interface status
Applies to Poling Engine only. Shows status irrespective
of whether the monitoring boxes (as above) are ticked.
This information is only refreshed when this window is
opened.
12 Edit dialler or profile Option to allows definition of a default profile which can
be applied to new or existing diallers to make setup
easier.
13 Exit options Remember that any changes will not be loaded into the
Polling Engines unless the correct option is selected.
Comentários a estes Manuais